Autoclave

Encyclopedia : A : AU : AUT : Autoclave


Front loading autoclaves are common
Enlarge
Front loading autoclaves are common

Stovetop autoclaves need to be monitored carefully, but have a very large capacity
Enlarge
Stovetop autoclaves need to be monitored carefully, but have a very large capacity

Multiple large autoclaves are used for processing substantial quantities of laboratory equipment prior to reuse, and infectious material prior to disposal.
Enlarge
Multiple large autoclaves are used for processing substantial quantities of laboratory equipment prior to reuse, and infectious material prior to disposal.

For the article about the early 1990s Washington, D.C.-based indie rock band, see Autoclave (band).
An autoclave is a pressurized device designed to heat aqueous solutions above their boiling point. It was invented by Charles Chamberland in 1879.[link]

Introduction

Under ordinary circumstances, heating water above the boiling point in an open vessel is impossible. Whenever the temperature rises up to 100° C, water ceases to warm any more. This is due to extensive evaporation that occurs during boiling. The process of evaporation takes all the heat, thus preventing water from further heating. If water is boiled long enough, it all turns to vapor.

However, if water is heated in a sealed vessel (such as an autoclave), it is possible to increase the boiling point. When the temperature reaches approximately 90° C, extensive evaporation takes place. Water vapor, being a gas by nature, creates excessive pressure within the vessel. As vapor pressure in the vessel reaches the value that corresponds to the temperature, evaporation ceases. Thereby, not all water turns into vapor. The higher the temperature, the higher is the pressure of the vapor. The heat generated under pressure is called latent heat and has more penetrative power to squeeze through bacteria and even their dormant, heat-resistant form — the spores. This works just fine on solid objects; when autoclaving hollow objects however (hypodermic needles, tools, etc.), we need to ensure that all of the trapped air inside the hollow compartments gets sucked out or otherwise it will act as thermal insulation for the bacteria inside.

Simple autoclaves use a single pulse pre-vacuum while a modern day autoclave has fractioned pre-vacuum that pulls the air out in several stages to achieve 100% steam penetration in the sterilization process.

Autoclaves are widely used in medicine and metallurgy.

Autoclaves in medicine

A medical autoclave is a device that uses steam to sterilise equipment and other objects. This means that all bacteria, viruses, fungi, and spores are inactivated. However, in 2003 scientists discovered a single-celled organism, Strain 121, that survives traditional autoclave temperatures. Prions also may not be destroyed by autoclaving.

Autoclaves work by allowing steam to enter, then maintaining pressure at 103 kPa (15 psi). This causes the steam to reach 121 °C, and this is maintained for at least 15 minutes. However, this technique is dated; modern autoclaves operate at higher temperature and pressures.

Autoclaves are found in many medical settings and other places that need to ensure sterility of an object. They were once more common, but many procedures today use single-use items rather than sterilized, reusable items. This first happened with hypodermic needles, but today many surgical instruments (forceps, needle holders, scalpel handles, etc.) are commonly single-use items rather than reusable.

Because damp heat is used, heat-labile products (such as some plastics) cannot be sterilised this way or they will melt. Some paper or other products that may be damaged by the steam must also be sterilised another way. In stovetop autoclaves, items should always be separated to allow the steam to penetrate the load evenly.

Chemiclave

Unlike the humid environment produced by conventional steam, the unsaturated chemical vapor method is a low-humidity process. No time-consuming drying phase is needed, because nothing gets wet. The heat-up time is shorter than for most steam sterilizers, and the heaters stay on between cycles to minimize warm-up time and increase the instrument turnover.

Autoclave quality assurance

Sterilization bags often have a “sterilization indicator mark” that typically darkens when sterilization temperatures have been reached. Comparing the mark on an unprocessed bag to a bag that has been properly cycled will show an obvious visual difference.
Enlarge
Sterilization bags often have a “sterilization indicator mark” that typically darkens when sterilization temperatures have been reached. Comparing the mark on an unprocessed bag to a bag that has been properly cycled will show an obvious visual difference.

There are physical, chemical and biological indicators that can be used to ensure an autoclave reached the correct temperature for the correct amount of time.

Chemical indicators can be found on medical packaging and autoclave tape, and these change color once the correct conditions have been met. This indicates that the object inside the package, or under the tape, has been autoclaved sufficiently.

Biological indicators include Attest devices. These contain spores of a heat resistant bacterium Bacillus stearothermophillus. If the autoclave did not reach the right temperature, the spores will germinate, and their metabolism will change the colour of a pH-sensitive chemical.

Physical indicators often consist of an alloy designed to melt only after being subjected to 121 °C for 15 minutes. If the metal has melted, the change will be visible.

As well as these separate indicators, autoclaves have temperature and pressure gauges visible from the outside.

There are certain plastics that can withstand repeated temperature cycling greater than the 121 degrees Celsius required for this process. PFA is an example.

Computer-controlled autoclaves use an F0 (F-naught) value to control the sterilization cycle. F0 values are set as the number of minutes of equivalent sterilization at 121°C (e.g: F0 = 15 min.). Since exact temperature control is difficult, the temperature is monitored, and the sterilization time adjusted accordingly.

Loading an Autoclave

(These directions are for a typical front loading autoclave, but apply to most autoclaves)

  1. Clean and inspect the autoclave regularly. Check the autoclave door gasket, drum, and steam return filter for corroded pipes.
  2. Use distilled De-ionized water, or other clean neutral pH water.
  3. Autoclave dissimilar metals (aluminum, brass, steel) in different loads as electroplating may occur which will permanently stain the tool.
  4. Use towels to separate instruments and absorb moisture if needed.
  5. Autoclave hinged instruments in the non locked open position, if locked the tool may become damaged (usually at the hinge).
  6. No sharp instruments should be allowed to touch other instruments.
  7. Do not over pack the autoclave, steam should be able to get to all sides of all pouches.

External links

 


From Wikipedia, the Free Encyclopedia. Original article here. Support Wikipedia by contributing or donating.
All text is available under the terms of the GNU Free Documentation License See Wikipedia Copyrights for details.