Self contained breathing apparatus
Encyclopedia : S : SE : SEL : Self contained breathing apparatus
- "SCBA" redirects here. For , see .
An SCBA typically has three main components: a high-pressure tank (e.g., 2200 psi to 4500 psi), a pressure regulator, and an inhalation connection (mouthpiece or face mask), connected together and mounted to a carrying frame.
There are two kinds of SCBA: open circuit and closed circuit.
Open-circuit
Open-circuit industrial breathing sets are filled with filtered, compressed air, the same air we breathe normally. The compressed air passes through a regulator, is inhaled by the user, then exhaled out of the system, quickly depleting the supply of air. Most modern SCBAs are open-circuit.Closed-circuit SCBAs
The closed-circuit type is a special SCBA which filters, supplements and recirculates exhaled gas (see rebreather for more information. It is used when a longer-duration supply of air is needed such as in mine rescue and in long tunnels. Before open-circuit SCBA was developed, most industrial breathing sets were rebreathers, such as the Siebe Gorman Proto and the Siebe Gorman Salvus. There also exists closed circuit SCUBA used underwater, which has the advantage of not releasing tell-tale bubbles, making it more difficult to detect divers involved in covert operations.Typical operation
A rescue/firefighter SCBA has a full-face mask, regulator, air cylinder, cylinder pressure gauge, and a harness with adjustable shoulder straps and waist belt which lets it be worn on the back. Its cylinder usually holds 30 or 45 minutes worth of air, but this can be less or more, commonly as low as 15 minutes or as high as 60 minutes.Air cylinders are made of aluminum, steel, or of a composite construction (usually fiberglass-wrapped aluminum.) The composite cylinders are the lightest in weight and are therefore preferred by fire departments (UK: fire brigades), but they also have the shortest lifespan and must be taken out of service after 15 years. Air cylinders must be hydrostatically tested every 3 years for composite cylinders, and every 5 years for metal cylinders. During extended operations, empty air cylinders can be quickly replaced with fresh ones and then refilled from larger tanks in a cascade system or from a air compressor brought to the scene.
Commonly an SCBA will be of the "positive pressure" type, which supplies a slight steady stream of air to stop toxic fumes or smoke from leaking into the mask. Not all SCBAs are positive pressure; others are of the "demand" type, which only supply air on demand (i.e., when the regulator senses the user inhaling). All fire departments and those working in toxic environments need to use the positive pressure SCBA for safety reasons.
As SCBA technology has evolved, different models have evolved for firefighting, versus those designed for where the set does not need to be heat resistant, such as in mining. In the USA, SCBAs used in firefighting must meet guidelines established by the National Fire Protection Association, NFPA Standard 1981. If an SCBA is labeled as "1981 NFPA compliant", it is designed for firefighting. The current version of the standard was published in 2002. Similarly, the National Institute for Occupational Safety and Health (NIOSH) has a certification program for SCBA that are intended to be used in chemical, biological, radiological, and nuclear (CBRN) environments. See [NIOSH Approved SCBAs].
Also known as
In Australia different firefighting agencies refer to SCBA by different acronyms in general terms. For example, the New South Wales Rural Fire Service refers to SCBA as CABA, Compressed Air Breathing Apparatus, and the New South Wales Fire Brigades refers to it as BA, Breathing Apparatus. Despite the different names, SCBA, CABA and BA here all refer to the same type of Open-circuit equipment.Scott Aviation, a company with World War II experience in providing oxygen systems for military air crews, was the first to manufacturer Open Circuit Self Contained Breathing Apparatus on a large scale for the fire service, utilizing compressed air since oxygen would be too hazardous for this use. Scott, now the Scott Health& Safety division of Tyco International (2006), coined the term AirPakĀ® for its product in the 1950's and owns that term as a Registered Trademark in the U.S. However, the word "airpack" has come into generic use as a synonym for SCBA, much to the Scott company's consternation.
Among the leading manufacturers of SCBA for the USA fire service are: Scott, Survivair, MSA, Interspiro, ISI (International Safety Instruments) and Draeger.
See also
- Glossary of firefighting terms
- PASS device, which is often integrated into an SCBA system
- Oxygen mask
- STAS; short-term air supply for self-rescue